Guardmaster Guard Locking safety relay with Time Delay (GLT), 1 Dual Channel Input (time delayed outputs - GLT), 1 N.O., PNP, 50mA, non-safety Immediate Auxiliary Outputs
SAFETY RELAY DATA | |
---|---|
Inputs | 1 Dual Channel Input (time delayed outputs - GLT) |
Single Wire Safe Input | 1 SWS Input |
Logic Configuration | Category 1 Stop, Time Delayed Outputs Rotary Switch Configured |
Immediate Safety Outputs | 2 OSSDs, 500mA |
Immediate Auxiliary Outputs | 1 N.O., PNP, 50mA, non-safety |
Delayed Safety Outputs | 2 OSSDs, 300mA |
Single Wire Safe Output | 1 SWS Output |
Power Supply | 24V DC |
Removable Terminals | Removable |
Reset | Configured Automatic/Manual or Manual Monitored Reset |
SAFETY RELAY INFORMATION | |
Relay Model | Guardmaster Guard Locking safety relay with Time Delay (GLT) |